| 897 | 52 | 17 |
| 下载次数 | 被引频次 | 阅读次数 |
选取了不同产地及不同等级的10批次金银花和白芷进行测定,并建立了微波消解-ICP-MS法测定中药材中5种有害元素含量的分析方法,各元素的线性关系良好,灵敏度(cps/ng/mL)959~18116,相关系数0.999992~1.000000,定量限0.03~0.3ng/mL,线性范围0~100ng/mL。因其低检出限及高灵敏度,该方法能满足中药材样品质量控制中5种有害元素的测定要求。为中药材中该5种有害元素的准确测定提供参考。
Abstract:It has been determined for 10 batches of honeysuckle and angelica from different areas and different levels,an analysis method has been established to test five harmful elements in TCM materials with microwave digestion-ICP-MS.The sensitivites of the method are 959~18 116 cps/ppb,the correlation coefficients are 0.999 992~ 1.000 000,and the quantitative restriction are 0.03~0.3 ng/mL for all those elements.Besides,the linear range are 0 ~100 ng/mL.Because of excellent detection limit and high sensitivity,the method can meet the testing requirements for controlling 5 harmful elements and can support the accurte test of these elements in TCM materials as reference.
[1]罗晓健,孙婷婷,高丽丽,等.中药重金属研究概况[J].江西中医学院学报,2007,19(6):88-90.
[2]陈晋红,刘大伟,汤毅珊,等.中药材重金属和农药残留的研究进展[J].中药新药与临床药理,2009,20(2):187-190.
[3]罗小莉,杨金蓉,李汝佳,等.中药中重金属元素测定的研究进展[J].实用医药杂志,2009,26(5):61-63.
[4]石世学,聂万达,潘力佳.中药中农药、重金属残留的分析方法概述[J].中草药,2007,38(2):310-312.
[5]王柯,王欣美.ICP-MS法测定中药材中13种元素[J].中国药学杂志,2005,40(15):1184-1187.
[6]杨美华,吴剑威,赵润怀.中药材中重金属检测及脱除技术研究进展[J].中国现代中药,2008,10(1):3-7.
[7]贾薇,江滨,曾元儿.ICP-MS法测定5种中药材中4种重金属的含量[J].中药新药与临床药理,2009,20(2):151-152.
[8]刘彦彦,李静,王栋,等.微波消解电感耦合等离子体质谱法测定3种中药材中4种重金属含量[J].时珍国医国药,2009,20(6):1435-1437.
[9]王志嘉,尤海丹,吴志刚.微波消解-原子荧光光谱法测定中药材中铅、镉、砷、汞、锑的含量[J].沈阳药科大学学报,2008,25(5):388-392.
[10]张立雯,张玉英.ICP-MS法测定中成药中5种有害元素的方法研究[J].中华中医药杂志,2009,24(3):358-360.
基本信息:
中图分类号:R284.1
引用信息:
[1]谭镭,吕昊,詹雁,等.微波消解-ICP-MS法测定金银花和白芷中5种有害重金属元素[J].中国测试,2009,35(06):78-80.
2009-11-30
2009-11-30